Diagnostics
12.1 Event and fault handling
Result
The settings for sending system event messages are configured.
The "severity" function is enabled.
Further notes
You disable the setting with the
You display the status of this function and other information
12.1.6.7

no severity

Description
With this command, you disable the setting for the threshold values for the sending of
system event notifications.
Requirement
You are in the EVENTS Configuration mode.
The command prompt is as follows:
cli (config-events) #
Syntax
Call up the command with the following parameters:
no severity { mail | log | syslog }
The parameters have the following meaning:
Parameter
mail
log
syslog
If you do not select any parameters from the parameter list, the default value is used.
Result
The settings for sending system event messages are configured.
900
command.
no severity
Description
The setting of the threshold value for
sending system event messages by e-
mail is disabled.
The setting of the threshold value for
entering system event messages in the
log table disabled.
The setting of the threshold value the
entering event messages in the Syslog
file is disabled.
SCALANCE XM-400/XR-500 Command Line Interface (CLI)