Panel-Button Control-Factory-Defaults; No Panel-Button Control-Factory-Defaults - Siemens SCALANCE XM-400 Configuration Manual

Simatic net industrial ethernet switches command line interface (cli)
Hide thumbs Also See for SCALANCE XM-400:
Table of Contents

Advertisement

4.3.1.1

panel-button control-factory-defaults

Description
With this command, you enable the following function of the "SELECT/SET" button:
● When display mode A "port status" is displayed, and the button is pressed for more than
12 seconds, there is a restart with the factory settings.
Requirement
You are in the Global configuration mode.
The command prompt is as follows:
cli(config)#
Syntax
Call the command without parameter assignment:
panel-button control-factory-defaults
Result
The function of the "SELECT/SET" button for restarting with factory settings is enabled.
Further notes
You disable this function with the
4.3.1.2

no panel-button control-factory-defaults

Description
With this command, you disable the following function of the "SELECT/SET" button:
● When display mode A "port status" is displayed, and the button is pressed for more than
12 seconds, there is a restart with the factory settings.
Requirement
You are in the Global configuration mode.
The command prompt is as follows:
cli(config)#
SCALANCE XM-400/XR-500 Command Line Interface (CLI)
Configuration Manual, 06/2016, C79000-G8976-C252-11
no panel-button control-factory-defaults
Functions specific to SCALANCE
4.3 Panel button
command.
149