Layer 3 functions
9.2 OSPFv2 (IPv4)
Syntax
Call the command without parameter assignment:
no ip ospf cost
Result
The costs are deleted.
Further notes
You create the costs with the
You show the configuration of the OSPF interface with the
command.
9.2.4.7

ip ospf dead-interval

Description
With this command, you specify the time that can elapse before the neighbor router is
assumed to have "failed". This means that no more Hello packets were received from it
during this time.
Note
This command is available only with layer 3.
Requirement
● The interface is an IPv4 interface.
● You are in the Interface configuration mode.
The command prompt is:
cli(config-if-$$$)#
Syntax
Call up the command with the following parameters:
ip ospf dead-interval <seconds (0-0x7fffffff)>
The parameter has the following meaning:
Parameter
seconds
556
command.
ip ospf cost
Description
Interval in seconds
SCALANCE XM-400/XR-500 Command Line Interface (CLI)
show ip ospf interface
Range of values / note
0 ... 0x7fffffff