Layer 2 management protocols
8.5 Ring redundancy and standby connection
Result
The counters are displayed.
8.5.5
Commands in the global configuration mode
This section describes commands that you can call up in the Global configuration mode.
In Privileged EXEC mode, enter the
Commands relating to other topics that can be called in the Global configuration mode can
be found in the relevant sections.
You exit the Global configuration mode with the
Privileged EXEC mode again.
8.5.5.1
ring-redundancy configuration
Description
With this command, you change to the Redundancy Configuration mode.
Requirement
You are in the Global Configuration mode.
The command prompt is as follows:
cli(config)#
Syntax
Call the command without parameters:
ring-redundancy configuration
Result
You are now in the Redundancy Configuration mode.
The command prompt is as follows:
cli(config-red)#
Further notes
You exit the Redundancy Configuration mode with the
474
command to change to this mode.
configure terminal
or
end
exit
or
end
SCALANCE XM-400/XR-500 Command Line Interface (CLI)
Configuration Manual, 06/2016, C79000-G8976-C252-11
command and are then in the
command.
exit