Summary of Contents for Siemens SCALANCE XR-100WG Series
Page 1
___________________ Introduction ___________________ Safety notices ___________________ SIMATIC NET Description of the device ___________________ Installation Industrial Ethernet switches SCALANCE XR-100WG ___________________ Connecting up ___________________ Upkeep and maintenance Operating Instructions ___________________ Technical specifications ___________________ Dimension drawings ___________________ Approvals 05/2017 C79000-G8976-C455-01...
Page 2
Note the following: WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation. If products and components from other manufacturers are used, these must be recommended or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any problems.
Introduction Purpose of the Operating Instructions These operating instructions support you when installing and connecting up devices of the SCALANCE XR-100WG product group. Validity of the Operating Instructions These operating instructions apply to the following devices: ● SCALANCE XR124WG Unless mentioned otherwise, the descriptions in these operating instructions refer to all devices of the SCALANCE XR-100WG product group named above in the section on validity.
Page 4
You will find the SIMATIC NET glossary on the Internet at the following address: 50305045 (http://support.automation.siemens.com/WW/view/en/50305045) Catalogs You will find the article numbers for the Siemens products of relevance here in the following catalogs: ● SIMATIC NET Industrial Communication / Industrial Identification, catalog IK PI ●...
Page 5
In order to protect plants, systems, machines and networks against cyber threats, it is necessary to implement – and continuously maintain – a holistic, state-of-the-art industrial security concept. Siemens’ products and solutions only form one element of such a concept. Customer is responsible to prevent unauthorized access to its plants, systems, machines and networks.
Page 6
Use of product versions that are no longer supported, and failure to apply latest updates may increase customer’s exposure to cyber threats. To stay informed about product updates, subscribe to the Siemens Industrial Security RSS Feed under https://support.industry.siemens.com/cs/ww/en/ps/15247/pm...
Safety notices Read the safety notices Note the following safety notices. These relate to the entire working life of the device. You should also read the safety notices relating to handling in the individual sections, particularly in the sections "Installation" and "Connecting up". CAUTION To prevent injury, read the manual before use.
Description of the device Product overview Article numbers Device Properties Article number SCALANCE 24 VDC Variant 6GK5 124-0BA00-2AR3 XR124WG 24 x 10/100 Mbps RJ-45 ports • 2 x 24 VDC, connector for the power supply on the front • 240 VAC variante 6GK5 124-0BA00-3AR3 24 x 10/100 Mbps RJ-45 ports •...
Description of the device 2.2 Device views Type Description Article number Power cable For Italy 6ES7 900-0EA00-0XA0 100 to 240 VAC, straight, 3 m Power cable For China 6ES7 900-0FA00-0XA0 100 to 240 VAC, straight, 3 m Device views 2.2.1 Device view of a 24 VDC variant The following figure shows an overview of the components of a 24 VDC variant of a SCALANCE XR124WG.
Description of the device 2.3 LED display 2.2.2 Device view of 240 VAC variant The following figure shows an overview of the components of a 240 VAC variant of a SCALANCE XR124WG. ① Electrical ports with port LEDs ② Integrated brackets for 19" rack mounting ③...
Page 14
Description of the device 2.3 LED display SCALANCE XR-100WG Operating Instructions, 05/2017, C79000-G8976-C455-01...
Installation Safety notices for installation Safety notices When installing the device, keep to the safety notices listed below. WARNING If a device is operated in an ambient temperature of more than 40 °C, the temperature of the device housing may be higher than 70 °C. The device must therefore be installed so that it is only accessible to service personnel or users that are aware of the reason for restricted access and the required safety measures at an ambient temperature higher than 40 ℃.
Page 16
Installation 3.1 Safety notices for installation WARNING When used in hazardous environments corresponding to Class I, Division 2 or Class I, Zone 2, the device must be installed in a cabinet or a suitable enclosure. Safety notices for use according to ATEX and IECEx If you use the device under ATEX or IECEx conditions you must also keep to the following safety notices in addition to the general safety notices for protection against explosion: WARNING...
Page 17
Installation 3.1 Safety notices for installation WARNING Explosion hazard Do not disconnect equipment when a flammable or combustible atmosphere is present. WARNING EXPLOSION HAZARD For operation the device is intended to be installed within an enclosure/control cabinet. The inner temperature of the enclosure/control cabinet corresponds to the ambient temperature of the device.
Page 18
Installation 3.1 Safety notices for installation Further notes CAUTION Use only approved components If you use components and accessories that are not approved for SIMATIC NET devices or their target systems, this may violate the requirements and regulations for safety and electromagnetic compatibility.
Installation 3.2 19" rack mounting 19" rack mounting Mounting CAUTION Risk of injury if subjected to irregular mechanical strain The device must be mounted in the 19" rack so that even if there is irregular mechanical strain, no dangerous situation can result. Figure 3-1 19"...
Page 20
Installation 3.2 19" rack mounting NOTICE Rack-mount instructions A) Elevated Operating Ambient - If installed in a closed or multi-unit rack, the operating ambient temperature of the rack environment may be greater than the room ambient. Therefore consideration should be given to installing the equipment in an environment compatible with the maximum ambient temperature (Tma) specified by the manufacturer.
Connecting up Safety when connecting up Safety notices When connecting up the device, keep to the safety notices listed below. If using power sources according to NEC Class 2 or LPS, please note the following information: WARNING The equipment is designed for operation with Safety Extra-Low Voltage (SELV) by a Limited Power Source (LPS).
Page 22
Connecting up 4.1 Safety when connecting up Safety notices when using the device according to Hazardous Locations (HazLoc) and FM. If you use the device under HazLoc or FM conditions you must also keep to the following safety notices in addition to the general safety notices for protection against explosion: WARNING EXPLOSION HAZARD You may only connect or disconnect cables carrying electricity when the power supply is...
Connecting up 4.2 Industrial Ethernet Industrial Ethernet Note Strain relief of the interfaces To prevent weights or mechanical movement that can affect an interface causing interrupted contact, fix the cables to a cable guide or rail at short intervals. R-45 connector technology The attachment to Industrial Ethernet uses RJ-45 connected technology with MDI-X assignment.
Connecting up 4.3 Wiring rules Autonegotiation Autonegotiation means the automatic detection/negotiation of the transmission rate and the operating mode of ports at the opposite end. This makes it possible to configure different devices automatically. Two components connected to a link segment can exchange information about the transfer and can adapt their settings to each other.
Connecting up 4.4 24 VDC power supply 24 VDC power supply CAUTION Overvoltage protection for the power supply cables If SCALANCE XR-100WGs are supplied over long 24 V power supply lines or networks, measures are necessary to prevent interference by strong electromagnetic pulses on the supply lines.
Connecting up 4.5 Power supply 240 VAC Position and assignment Figure 4-1 Position of the terminal block on a SCALANCE XR-100WG Contact Assignment Contact Assignment +24 VDC +24 VDC Ground Ground Power supply 240 VAC Notes on the power supply WARNING Danger from line voltage for devices with a 240 VAC power supply This device can only function correctly and safely if it is transported, stored, set up, and...
Connecting up 4.6 Functional ground Note Use in IT networks When used in IT networks, the power supply 240 VAC also applies to the connected IT network: Phase-to-phase. Information on the power supply ● The power supply is connected using an IEC plug C13/C14. The device installation plug C14 is located on the rear panel of the device.
Page 28
Connecting up 4.6 Functional ground Functional ground EMC disturbances are diverted to ground via the functional ground. This ensures the immunity of the data transmission. The functional ground must be implemented with low impedance. The connection of the functional ground must be established directly on the mounting plate or the DIN rail terminal. Connecting up functional ground ①...
LED and all port LEDs to go off. The functionality of the SCALANCE XR-100WG is no longer available. A power supply of at least 19.2 V is necessary for correct operation. Device defective If a fault develops, please send the device to your SIEMENS service center for repair. Repairs on-site are not possible. SCALANCE XR-100WG...
Technical specifications Technical specifications of the SCALANCE XR124WG (24 VDC variant) The following technical specifications apply to the SCALANCE XR124WG. Technical specifications Attachment to Industrial Ethernet Electrical connectors Quantity Connector RJ-45 jack Properties Half/full duplex, MDI-X pinning Transmission speed 10 / 100 Mbps Electrical data Power supply Design...
Technical specifications 6.2 Technical specifications of the SCALANCE XR124WG (240 VAC variant) Technical specifications of the SCALANCE XR124WG (240 VAC variant) The following technical specifications apply to the SCALANCE XR124WG. Technical specifications Attachment to Industrial Ethernet Electrical connectors Quantity Connector RJ-45 jack Properties Half/full duplex, MDI-X pinning...
Technical specifications 6.3 Cable lengths Cable lengths The following technical specifications apply to the following devices: ● SCALANCE XR124WG Cable Permitted cable length IE TP torsion cable 0 to 45 m with IE FC Outlet RJ-45 + 10 m TP cord + 10 m TP cord IE TP torsion cable 0 to 55 m...
Technical specifications 6.5 Mechanical stability (in operation) Switching properties Full wire speed switching Frame length (bytes) Number of frames per second (at 100 Mbps) 148810 84459 45290 23496 1024 11973 1280 9615 1518 8127 Note The number of SCALANCE XR-100WG modules connected in a line influences the frame delay.
You can check which of the following approvals have been granted for your product by the markings on the type plate. Current approvals on the Internet You will find the current approvals for the product on the Internet pages of Siemens Industry Online Support (http://support.automation.siemens.com/WW/view/en/33118389/134200). Installation guidelines...
Page 38
You will find the EC declaration of conformity for these products on the Internet pages of Siemens Industry Online Support (http://support.automation.siemens.com/WW/view/en/33118389/134200). The EC Declaration of Conformity is available for all responsible authorities at:...
Page 39
Area". You will find this document • on the data medium that ships with some devices. • on the Internet pages of Siemens Industry Online Support (http://support.automation.siemens.com/WW/view/en). Enter the document identification number C234 as the search term. The SIMATIC NET products meet the requirements of the EC directive 94/9/EC "Equipment and Protective Devices for Use in Potentially Explosive Atmospheres”.
Page 40
Approvals IECEx The SIMATIC NET products meet the requirements of explosion protection according to IECEx. IECEx classification: Ex nA IIC T4 Gc DEK 14.0025X The products meet the requirements of the following standards: ● IEC 60079-15 (Explosive atmospheres - Part 15: Equipment protection by type of protection "n") ●...
Page 41
Approvals The product meets the requirements of the standards: ● Factory Mutual Approval Standard Class Number 3611 ● FM Hazardous (Classified) Location Electrical Equipment: Non Incendive / Class I / Division 2 / Groups A,B,C,D / T4 and Non Incendive / Class I / Zone 2 / Group IIC / T4 Note Only variants with 24 VDC power supply meet the requirements of this approval.
Page 42
Only variants with 24 VDC power supply meet the requirements of this approval. Safety of electrical equipment In the version put into circulation by Siemens AG, the SIMATIC NET products described in these Operating Instructions conform to the regulations of the following European directive: ●...
Page 44
Index Safety notices for installation, 15 general, 9 Use in hazardous areas, 9, 15, 21 when connecting up, 21 SIMATIC NET glossary, 4 SIMATIC NET manual, 4 System manual, 4, 18, 37 Weight, 31, 32 Wiring, 24 SCALANCE XR-100WG Operating Instructions, 05/2017, C79000-G8976-C455-01...