No Time Dst - Siemens SCALANCE XM-400 Configuration Manual

Simatic net industrial ethernet switches command line interface (cli)
Hide thumbs Also See for SCALANCE XM-400:
Table of Contents

Advertisement

System time
5.1 System time setting
Syntax
Call up the command with the following parameters:
time dst recurring <name(16)> begin {<week(1-5)> | last} <weekday> <month> <hour> end
{<week(1-5)> | last} <weekday> <month> <hour>
The parameters have the following meaning:
Parameter
name
begin
week
last
weekday
month
hour
end
Result
The entry for the start and end of daylight saving time was created.
Further notes
You display the settings for the daylight saving time changeover with the
command.
5.1.2.5

no time dst

Description
With this command you delete the entry for the start and end of daylight saving time with the
specified name. If you do not specify a name as the parameter, all entries are deleted.
Requirement
You are in the Global configuration mode.
The command prompt is as follows:
cli(config)#
160
Description
Name of the entry
Keyword for the start of daylight saving
time.
Calendar week in a month
Keyword for the last calendar week in a
month
Weekday
Month
Hour
Keyword for the end of daylight saving
time.
SCALANCE XM-400/XR-500 Command Line Interface (CLI)
Range of values / note
maximum 16 characters
-
1 ... 5
-
monday, tuesday, wednesday,
thursday, friday, saturday, sunday
january, february, march, april,
may, june, july, august, septem-
ber, october, november, decem-
ber
0 ... 23
-
Configuration Manual, 06/2016, C79000-G8976-C252-11
show dst info

Advertisement

Table of Contents
loading