Security and authentication
11.3 MAC access control list
Requirement
● A MAC access control list has been created.
● You are in the Interface configuration mode.
The command prompt is:
cli(config-if-$$$)#
Syntax
Call up the command with the following parameters:
mac access-group <access-list-number(1-128)>{in|out}
The parameters have the following meaning:
Parameter
access-list-number
in
out
Result
The packets are filtered according to the access control list (ACL).
Further notes
You disable the setting with the
You display the statistical data of the access control list with the
command.
11.3.3.2

no mac access-group

Description
With this command, you disable the access control of the packets of an interface.
Requirement
You are in the Interface configuration mode.
The command prompt is as follows:
cli(config-if-$$$)#
828
Description
Number of the access control list
Specifies that incoming packets are
filtered
Specifies that outgoing packets are
filtered
no mac access-group
SCALANCE XM-400/XR-500 Command Line Interface (CLI)
Range of values / note
1 ... 128
-
-
command.