Layer 3 functions
9.8 Route maps (IPv4 / IPv6)
9.8.3.19

set metric

Description
With this command, you specify whether the routing information is forwarded with a changed
metric.
Note
This command is available only with layer 3.
Requirement
You are now in the Route maps configuration mode.
The command prompt is as follows:
cli(config-rmap-$$$)#
Syntax
Call up the command with the following parameters:
set metric <value(0-0xffffff)>
The parameter has the following meaning:
Parameter
value
Result
The routing information is forwarded with a changed metric.
Further notes
You delete the setting that the metric of the routing information is changed with the
metric
You change to the Route maps configuration mode with the command
You display the setting and other information with the
730
Description
Value of the metric
command.
Range of values / note
0 ... 0xffffff
Enter the new value for the metric with which the routing
information will be forwarded.
You can enter the value in decimal or hexadecimal.
show route-map
SCALANCE XM-400/XR-500 Command Line Interface (CLI)
Configuration Manual, 06/2016, C79000-G8976-C252-11
no set
.
route-map
command.