2. Movable Drive Face Position Sensor Installation
Inspection
Remove the movable drive face position sensor
(page 24-51).
Check if the slot of the movable drive face posi-
tion sensor and sensor shaft are aligned.
Is the position sensor installed correctly?
YES
– GO TO STEP 3.
NO
– Install the movable drive face position
sensor correctly, then GO TO STEP 6.
3. Movable Drive Face Position Sensor Resistance
Inspection 1
Measure the resistance at the movable drive face
position sensor 3P connector of the sensor side.
CONNECTION: A – B
B – C
A – C
STANDARD:
0 – 6.0 kΩ (20°C/68°F)
Is the resistance within 0 – 6.0 k Ω (20 ° C/68 ° F)?
YES
– GO TO STEP 4.
NO
– Faulty movable drive face position sen-
sor
4. Movable Drive Face Position Sensor Resistance
Inspection 2
Measure the resistance at the movable drive face
position sensor 3P connector terminals of the
sensor side by turning the sensor shaft groove
of sensor with your fingers.
• Do not damage the movable drive face posi-
tion sensor.
CONNECTION: A – B
STANDARD:
0 – 6.0 kΩ (20°C/68°F)
Is there resistance within 0 – 6.0 k Ω (20 ° C/68 ° F)?
YES
– GO TO STEP 5.
NO
– Faulty movable drive face position sen-
sor
Honda S Matic System (NSS250A)
Align
3P CONNECTOR
(Sensor side/male terminals)
B
B
A
A
3P CONNECTOR
(Sensor side/male terminals)
POSITION SENSOR
C
C
24-27