Honda NSS250S Manual page 247

Hide thumbs Also See for NSS250S:
Table of Contents

Advertisement

Place the bank angle sensor is horizontal (normal
If you check this
position) as shown, and ignition switch ON and
test, the ignition
engine stop switch " ".
switch OFF, then
turn the ignition
The bank angle sensor is normal if the engine stop
switch ON and
relay clicks and power supply is closed.
engine stop switch
Incline the bank angle sensor approximately 49 ± 4°
" ".
to the left or right with keep the ignition switch ON
and engine stop switch " ".
The bank angle sensor is normal if the engine stop
relay clicks and power supply is open.
INPUT VOLTAGE/GROUND LINE
INSPECTION
• Check the bank angle sensor system inspection
(page 6-92) before checking the input voltage/
ground line.
1. Input Voltage Line Inspection
Turn the ignition switch OFF.
Disconnect the bank angle sensor 3P (Black) con-
nector (page 6-94).
Turn the ignition switch ON and engine stop
switch " ".
Measure the voltage at the bank angle sensor 3P
(Black) connector of wire side and ground.
CONNECTION: Black (+) – Ground
Is there battery voltage?
YES
NO
2. Engine Stop Relay Coil Line Inspection
Measure the voltage at the bank angle sensor 3P
(Black) connector of wire side and ground.
CONNECTION: Black/orange (+) – Ground
Is there battery voltage?
YES
NO
maxiscooter-club.ru
– GO TO STEP 2.
– • Open circuit in Black wire
• Blown fuse (MAIN B or ECU, IGN
fuse)
– GO TO STEP 3.
– • Open circuit in Black/orange wire
• Faulty engine stop relay
• Faulty engine stop switch
FUEL SYSTEM (PGM-FI)
49° bank angle position
NORMAL POSITION 49 ± 4° (approximately)
49 ± 4° (approximately)
BANK ANGLE SENSOR 3P CONNECTOR
(Wire side/female terminals)
Black
BANK ANGLE SENSOR 3P CONNECTOR
(Wire side/female terminals)
Black/orange
6-93

Advertisement

Table of Contents
loading

This manual is also suitable for:

Nss250a

Table of Contents