Release Link - Avaya Definity SI Maintenance Manual

Table of Contents

Advertisement

Maintenance Commands and Trouble-Clearing Aids

release link

The release link command activates MOs associated with a specified link.
Hardware tests are executed to verify that equipment is functioning properly.
Action/
Object
Qualifier
Qualifier Description
release
link-id
Number associated with each link (1–8).
link
1 through 4 reside on Processor Interface circuit
packs "1a1" or "1b1"
5 through 8 reside on Processor Interface circuit
pack "1a2" or "1b2."
Examples:
release link 1
release link 8
Output
The following output example is a display of release link 1.
release link 1
Port
Maintenance Name
01C0301
PI-LINK
Command successfully completed
Field descriptions
Port
Maintenance Name
Alt. Name
Result
Error Code
8-256
Issue 4 May 2002
COMMAND RESULTS
Alt. Name
Result
Error Code
PASS
Port address (cabinet-carrier-slot-circuit) of the busied out or
released maintenance object. Port address represents the
link-id.
The type of maintenance object that is being released.
Not applicable.
Success status of a busied out object (PASS, ABORT, FAIL)
System-generated description of a command failure.
Feature
Logins
Defaults
Interactions
init
none
none
inads
craft
555-233-123

Advertisement

Table of Contents
loading