AUX user interface view
Parameters
1: Sets the stopbits to 1.
1.5: Sets the stopbits to 1.5.
2: Sets the stopbits to 2.
Description
Use the stopbits command to set the stopbits of the user interface.
Use the undo stopbits command to revert to the default stopbits.
Execute these two commands in AUX user interface view only.
By default, the stopbits is 1.
The Switch 5500-EI does not support communication with a terminal emulation program with
stopbits set to 1.5.
Changing the stop bits value of the switch to a value different from that of the terminal emulation
utility does not affect the communication between them.
Examples
# Set the stop bits to 2.
<Sysname> system-view
System View: return to User View with Ctrl+Z.
[Sysname] user-interface aux 0
[Sysname-ui-aux0] stopbits 2

telnet

Syntax
telnet { hostname | ip-address } [ service-port ] [ source-interface interface-type interface-number |
source-ip ip-address ]
View
User view
Parameters
hostname: Host name of the remote device, a string of 1 to 20 characters.
ip-address: IPv4 address of the remote device.
service-port: Number of the TCP port through which the remote device provides Telnet service. This
argument ranges from 0 to 65535, and defaults to 23.