display rmon alarm

Syntax
display rmon alarm [ entry-number ]
View
Any view
Parameters
entry-number: Alarm entry index, in the range 1 to 65535.
Description
Use the display rmon alarm command to display the configuration of a specified alarm entry or all the
alarm entries. The configuration information includes: sampling type, sampled node, sampling interval,
rising and falling thresholds that trigger alarms, the condition under which an alarm is triggered, and the
last sampled value.
Related commands: rmon alarm.
Examples
# Display the configuration of all the alarm entries.
<Sysname> display rmon alarm
Alarm table 1 owned by user1 is VALID.
Samples type
Variable formula
Sampling interval
Rising threshold
Falling threshold
When startup enables
Latest value
Table 2-1 display rmon alarm command output description
Alarm table
user1
Valid
Samples type
Variable formula
: absolute
: 1.3.6.1.2.1.16.1.1.1.4.1<etherStatsOctets.1>
: 20(sec)
: 100(linked with event 1)
: 10(linked with event 2)
: risingOrFallingAlarm
: 5510006
Field
Index of an entry in the alarm entry
Entry owner: user1
The alarm entry identified by the index is valid.
Sampling type, which can be absolute or delta
The sampled node
2-1