Poe Disconnect; Poe Enable - 3Com 5500-EI PWR Reference Manual

Hide thumbs Also See for 5500-EI PWR:
Table of Contents

Advertisement

<Sysname> display poe temperature-protection
The temperature protection is enabled.

poe disconnect

Syntax
poe disconnect { ac | dc }
undo poe disconnect
View
System view
Parameters
ac: Specifies the PD disconnection detection mode as ac.
dc: Specifies the PD disconnection detection mode as dc.
Description
Use the poe disconnect command to configure a PD disconnection detection mode.
Use the undo poe disconnect command to restore the default.
The default PD disconnection detection mode is AC.
Note that change to the PD disconnection detection mode may lead to power-off of some PDs.
Examples
# Set the PD disconnection detection mode to DC.
<Sysname> system-view
[Sysname] poe disconnect dc

poe enable

Syntax
poe enable
undo poe enable
View
Ethernet port view
Parameters
None
Description
Use the poe enable command to enable the PoE feature on a port.
Use the undo poe enable command to disable the PoE feature on a port.
By default, the PoE feature on a port is enabled by the default configuration file when the device is
delivered.
1-6

Advertisement

Chapters

Table of Contents
loading

This manual is also suitable for:

5500-ei series

Table of Contents