undo timer quiet
View
HWTACACS scheme view
Parameters
minutes: Wait time before primary server state restoration, ranging from 1 to 255 minutes.
Description
Use the timer quiet command to set the time that the switch waits before it tries to
re-communicate with the primary server and restore the status of the primary server to active.
Use the undo timer quiet command to restore the default wait time.
By default, the switch waits five minutes.
Related commands: display hwtacacs.
Examples
# Configure the switch to wait 10 minutes before it tries to restore the status of the primary server
to active.
<Sysname> system-view
System View: return to User View with Ctrl+Z.
[Sysname] hwtacacs scheme hwt1
[Sysname-hwtacacs-hwt1] timer quiet

timer realtime-accounting

Syntax
timer realtime-accounting minutes
undo timer realtime-accounting
View
HWTACACS scheme view
Parameters
minutes: Real-time accounting interval, in minutes. It ranges from 3 to 60 and must be a multiple
of 3.
Description
Use the timer realtime-accounting command to set the real-time accounting interval.
Use the undo timer realtime-accounting command to restore the default real-time accounting
interval.
By default, the real-time accounting interval is 12 minutes.
Note that: