3Com 5500-EI PWR Reference Manual page 945

Hide thumbs Also See for 5500-EI PWR:
Table of Contents

Advertisement

View
Any view
Parameters
prialarm-entry-number: Extended alarm entry Index, in the range 1 to 65,535.
Description
Use the display rmon prialarm command to display the configuration of an RMON extended alarm
entry. If you do not specify the prialarm-entry-number argument, the configuration of all the extended
alarm entries is displayed.
The information in an extended alarm entry includes: sampling type, variable formula of the sampled
node, sampling interval, rising and falling thresholds that trigger an alarm, the condition under which an
alarm is triggered, and the last sampled value.
Related commands: rmon prialarm.
Examples
# Display the configuration of all the extended RMON alarm entries.
<Sysname> display rmon prialarm
Prialarm table 1 owned by user1 is VALID.
Samples type
Variable formula
Description
Sampling interval
Rising threshold
Falling threshold
When startup enables
This entry will exist : forever.
Latest value
Table 2-5 display rmon prialarm command output description
Prialarm table
owned by user1
VALID
Samples type
Variable formula
Description
Sampling interval
Rising threshold
Falling threshold
: absolute
: ((.1.3.6.1.2.1.16.1.1.1.4.1)*100)
:
: 10(sec)
: 10000(linked with event 1)
: 2000(linked with event 1)
: risingOrFallingAlarm
: 0
Field
2-6
Description
Index of an entry in the extended alarm table
Entry owner: user 1
The alarm entry identified by the index is valid.
Sampling type: absolute or delta
Variable formula of the sampled node
Description
Sampling interval in seconds. The system
collects statistics of the port at this interval.
Rising threshold. When the sampled value
equals or exceeds the rising threshold, an alarm
is triggered.
Falling threshold. When the sampled value
equals or falls under the falling threshold, an
alarm is triggered.