Rmon Statistics - 3Com 5500-EI PWR Reference Manual

Hide thumbs Also See for 5500-EI PWR:
Table of Contents

Advertisement

Falling threshold: 5
Event 1 is triggered when the change ratio is larger than the rising threshold.
Event 2 is triggered when the change ratio is less than the falling threshold.
The alarm entry is valid forever.
Entry owner: user1
<Sysname> system-view
System View: return to User View with Ctrl+Z.
[Sysname] interface Ethernet 1/0/1
[Sysname-Ethernet1/0/1] rmon statistics 1
[Sysname-Ethernet1/0/1] quit
[Sysname]
rmon
rising_threshold 50 1 falling_threshold 5 2 entrytype forever owner user1
# Remove the extended alarm entry numbered 2 from the extended alarm table.
[Sysname] undo rmon prialarm 2

rmon statistics

Syntax
rmon statistics entry-number [ owner text ]
undo rmon statistics entry-number
View
Ethernet port view
Parameters
entry-number: Statistics entry Index, in the range 1 to 65535.
owner text: Specifies the owner of the entry, a string of 1 to 127 characters.
Description
Use the rmon statistics command to add an entry to the statistics table. If you do not specify the owner
text keyword/argument combination, the owner of the entry is displayed as "null".
Use the undo rmon statistics command to remove an entry from the statistics table.
The RMON statistics management function is used to take statistics of the usage of the monitored ports
and errors occurred on them. The statistics includes the number of the following items:
Collisions
Packets with CRC errors
Undersize/Oversize packets
Broadcast/Multicast packets
Received packets
Received bytes
prialarm
2
((.1.3.6.1.2.1.16.1.1.1.4.1)*100)
2-14
test
10