slot erase
If you specify a slot that contains a line module, you erase the configuration of
the line module and the I/O modules or IOAs associated with it. To erase the
configuration of a specific IOA on the E120 or E320 router, use "adapter accept"
on page 369 command.
Depending on the slot's previous configuration, the router might take a few
moments to execute this command.
The following is a sample log message resulting from putting an OC3 line module
in a slot that was previously configured for a line module:
ERROR 02/07/2003 15:16:20 system (slot 3): boardId mismatch: read 0x6 (OC3
dual port without classifier), configured 0x2e (OC12 ATM)
ERX-00-17-04(config)# slot accept
Please wait....
ERX-00-17-04(config)#ERROR 02/07/2003 15:16:31 system (slot 3):
unrecognized board type (0x6)
To resolve the problem, issue the slot accept command for slot 3.
Example 1 Accepts the configuration of the module in slot 3
host1(config)#slot accept 3
Example 2 Accepts the configuration of the specified SRP module and the SC
subsystem in slot 7 (applies only to E120 and E320 routers)
host1(config)#slot accept 7
Example 3 Accepts the configuration of the SC on the SRP module in slot 7
(applies only to E120 and E320 routers)
host1(config)#slot accept 7 srp
There is no no version.
See slot accept.
Use to delete the configuration of the module in the selected slot before you
install a different type of module.
This command enables you to create a fresh configuration for the module installed
in the slot.
You cannot use this command on a primary SRP module; however, you can use
it on a standby SRP module.
If you specify a slot on the E120 or E320 router that contains an SRP module,
you erase the configuration of the SC subsystem on that slot by default. You do
not, however, erase the configuration of the fabric slice that resides on the slot.
Use the srp keyword to erase only the configuration of the portion of the SC
subsystem that resides on a specified SRP module.
Use the fabric keyword to erase only the configuration of the fabric slice
that resides on the specified SRP module.
Replacing IOAs on the E120 Router and the E320 Router