Wrong Digest Report PDUs Number of packets received by the SNMP
engine that were dropped because they did not contain the expected
digest value
Decryption Error Report PDUs Number of packets received by the
SNMP engine that were dropped because they could not be decrypted
Example
host1#show snmp
Contact: Joe Administrator
Location: Network Lab, Bldg 3 Floor 1
538 SNMP packets input
0 Bad SNMP version errors
0 Unknown community name
0 Illegal operation for community name supplied
0 Encoding errors
695 Number of requested variables
0 Number of altered variables
26 Get-request PDUs
512 Get-next PDUs
0 Set-request PDUs
0 Unknown security models
0 Unavailable contexts
538 SNMP packets out
0 Too big errors (Maximum packet size 1500)
10 No such name errors
0 Bad values errors
0 General errors
538 Get-response PDUs
0 SNMP trap PDUs
0 Invalid Message Report PDUs
0 Unknown PDU Handler Report PDUs
0 Unknown Context Report PDUs
0 Unsupported Security Level Report PDUs
0 Not in time Window Report PDUs
0 Unknown Username Report PDUs
0 Unknown Engine ID Report PDUs
0 Wrong Digest Report PDUs
0 Decryption Error Report PDUs
See show snmp.
Use to display information about the groups you configured.
Field descriptions
Group Name Name of the group
Model Security model; for example, user-based security model (USM)
Level Method for authentication and privacy
none No authentication and no privacy
auth Authentication only
priv Authentication and privacy