Specifying The Type Of Performance; Table 42: Combinations Of Line Modules For Line Rate Performance Srp-10G Module In An Erx1410 Router; Table 43: Combinations Of Line Modules For Line Rate Performance Srp-5G+ Module In An Erx705 Router - Juniper SYSTEM BASICS - CONFIGURATION GUIDE V 11.1.X Configuration Manual

System basics configuration guide software for e series broadband services routers
Table of Contents

Advertisement

JUNOSe 11.1.x System Basics Configuration Guide
Table 42: Combinations of Line Modules for Line Rate Performance SRP-10G Module
in an ERX1410 Router
Table 43: Combinations of Line Modules for Line Rate Performance SRP-5G+ Module
in an ERX705 Router

Specifying the Type of Performance

After you have installed a suitable combination of line modules, you can specify a
different type of performance. To specify the type of performance:
1.
2.
376
Configuring Performance Rate of Line Modules on ERX7xx Models and the ERX1410 Router
Possible Combinations of Line Modules
One supported line module and two
empty slots in any slot group
NOTE: The SRP-10G module supports
all line modules listed in Table 40 on
page 374.
Two OCx/STMx ATM line modules
and one GE/FE module and one
empty slot in any slot group
(bandwidth oversubscription enabled)
One OC3/STM1 GE/FE module in any
slot (bandwidth oversubscription
disabled)
Possible Combinations of Line
Modules In Slot Groups
NOTE: The total bandwidth of all line modules must not exceed 5 Gbps. To make optimal use
of the available bandwidth, put line modules that require maximum bandwidth in slot 2, 3, or
4.
One supported line module
and one empty slot in slot
group 1
NOTE: The SRP-5G+
module supports all line
modules listed in Table 40
on page 374.
Two OCx/STMx ATM line
modules in slot group 1
One cOCx/STMx, COCX-F3,
CT3/T3 FO, GE/FE, IPSec
Service, or OCx/STMx line
module in slot groups 2, 3,
and 4
Issue the show bandwidth oversubscription command.
If the setting is not the one you want, enable or disable bandwidth
oversubscription.
Examples of Allowed
Combinations
One COCX-F3 line
module in slot group
1, a GE/FE line
module in slot group
2, and a OCx/STMx
POS line module in
slot group 3
Examples of Allowed
Combinations
Two OCx/STMx ATM
line modules (total
2.44 Gbps) in slot
group 1, and a GE/FE
line module
(2.46 Gbps) in slot
group 4
Two OCx/STMx ATM
line modules (total
2.44 Gbps) in slot
group 1, and a
COCX-F3 line module
in slot group 2
Examples of Forbidden
Combinations
Three OCx/STMx
ATM line modules
in any slot group
Two GE/FE line
modules in any
slot group
Examples of Forbidden
Combinations
Two OCx/STMx ATM line
modules (total 2.44 Gbps)
in slot group 1, a GE/FE
line module (2.46 Gbps)
in slot group 3, and an
OCx/STMx POS line
module (2.46 Gbps) in slot
4 (violates chassis
limitation)
Two OCx/STMx POS line
modules (total 4.92 Gbps)
in slot group 1 (violates
slot group limitation)

Advertisement

Table of Contents
loading

This manual is also suitable for:

Junose 11.1

Table of Contents