Monitoring Statistics

You can set a baseline and view statistics on the Fast Ethernet port of the SRP module
in the same way that you would for other Ethernet interfaces. See JUNOSe Physical
Layer Configuration Guide.

Monitoring the Ethernet Configuration for the SRP Module

Slots 0 and 1 are reserved for SRP modules on ERX7xx models; slots 6 and 7 are
reserved for SRP modules on ERX14xx models, the E120 Router, and the E320
Router. When you configure the Fast Ethernet interface on an SRP module, the output
of the show configuration command always indicates that the interface is configured
in the lower of the two slots (slot 0 or slot 6). This indication is true if you configure
the interface on a redundant SRP module in the higher slot or even if you have only
one SRP module and it is installed in the higher slot, as shown in the following
example:
host1#show version
Juniper Edge Routing Switch ERX-700
Copyright (c) 1999-2005 Juniper Networks, Inc.
System Release: erx_7-1-0.rel Partial
System running for: 25 days, 3 hours, 31 minutes, 5 seconds
slot
---- ------- ---------- ------- ----- ------------------ --------------
0
1
2
3
4
5
6
Use to select a Fast Ethernet interface on a line module or an SRP module.
On ERX7xx models, ERX14xx models, and the ERX310 router, specify the Fast
Ethernet interface management port by using the slot/port format.
On the E120 and E320 routers, you can specify the Fast Ethernet port on the
SRP IOA by using the slot/adapter/port format. The port on the SRP IOA is always
identified as 0.
Example 1 Selects a Fast Ethernet management port on ERX7xx models,
ERX14xx models, or the ERX310 router
host1(config)#interface fastEthernet 0/0
Example 2 Selects a Fast Ethernet management port on the E320 Broadband
Services Router
host1(config)#interface fastEthernet 6/0/0
Use the no version to remove IP from an interface or subinterface.
See interface fastEthernet.
Version: 7.1.0 [BuildId 4518]
(since THU DEC 22 2005 11:36:41 UTC)
state
type
admin
standby SRP-10Ge
enabled
online
SRP-10Ge
enabled
---
---
---
---
---
---
online
CT3-12
enabled
online
OC3-4A-APS enabled
online
GE
enabled
All rights reserved.
(December 21, 2005
spare
running release
---
erx_7-1-0.rel
---
erx_7-1-0.rel
---
---
---
---
---
erx_7-1-0.rel
---
erx_7-1-0.rel
---
erx_7-1-0.rel
Managing the Ethernet Port on the SRP Module
Chapter 6: Managing Modules
11:23)
slot uptime
---
25d03h:28m:49s
---
---
25d03h:24m:46s
25d03h:24m:22s
25d03h:24m:44s
403