Juniper SYSTEM BASICS - CONFIGURATION GUIDE V 11.1.X Configuration Manual page 397

System basics configuration guide software for e series broadband services routers
Table of Contents

Advertisement

3.
host1#show version
Juniper Edge Routing Switch E120
.......
slot
state
type
admin
---- ------- ------- -------
0
---
---
---
1 online
LM-10 disabled (admin) ---
2
online
LM-10A-ADV
enabled
3
---
---
---
.......
4.
5.
host1#show version
Juniper Edge Routing Switch E120
.......
slot
state
type
admin
---- ------- ------- -------
0
---
---
---
1
online
LM-4 disabled (mismatch)---
2
online
LM-10A-ADV
enabled
3
---
---
---
.......
6.
TIP: If the line module is in a redundancy group and you did not disable redundancy
in Step 1, the system switches to the spare line module. The system reloads both
the replaced line module and the spare line module when you issue the slot replace
command.
7.
host1(config)#slot disable 1
After the line module has booted, issue the show version command to ensure
that the status of the line module is disabled (admin).
running
spare
release
----- ------------- -------------
---
9-1-0b0-9.rel 1d08h:32m:29s
---
10-1-0b1-6-A.rel 2d19h:29m:18s
---
---
Remove the current line module and insert the new line module without removing
the IOA.
For example, remove the ES2 4G LM and insert the new ES2 10G LM or ES2 10G
ADV LM. Do not remove the ES2-S1 GE-8 IOA or the ES2-S1 Redund IOA.
After the new line module has booted, issue the show version command to
ensure that the status of the line module is disabled (mismatch).
running
spare
release
----- ------------- -------------
---
---
---
9-1-0b0-9.rel 1d08h:32m:29s
---
10-1-0b1-6-A.rel 2d19h:29m:18s
---
---
Issue the slot replace command on the slot.
host1(config)#slot replace 1
If you disabled redundancy for the slot in Step 1, enable redundancy when the
replacement line module has come online.
Replacing Line Modules on ERX Routers, the E120 Router, and the E320 Router
slot uptime
---
---
---
slot uptime
---
Chapter 6: Managing Modules
367

Advertisement

Table of Contents
loading

This manual is also suitable for:

Junose 11.1

Table of Contents