*** system operational: no
slot
type
----
------------------
0
LM-4
0/1
GE-4 IOA
6
SRP-100
6
SFM-100
6/0
SRP IOA
7
SFM-100
8
SFM-100
9
SFM-100
10
SFM-100
13
LM-4
13/0
GE-4 IOA
fabric temperature ranges
below -5C is too cold
above 79C is too hot
low temperature warning below 10C
high temperature warning above 70C
processor temperature ranges
below -5C is too cold
above 79C is too hot
low temperature warning below 10C
high temperature warning above 70C
IOA temperature ranges
below -5C is too cold
above 79C is too hot
low temperature warning below 10C
high temperature warning above 70C
Example 3 Displays the environment on an E120 router
host1#show environment all
chassis: 11 slot (id 0x8, rev. 0x0)
fabric: 120 Gbps (rev. 1)
fans: fanSubsystemOk
nvs: ok (998MB flash disk, 14% full), matches running config
power: A ok, B not present
srp redundancy: mode is file-system-synchronization
enabled, switch-on-error enabled
in sync
slots: ok
online: 1 2 6
standby: 7
empty: 0 3 5
fabric slots: ok
online: 6 7 8 9 10
line redundancy: none
temperature: ok
timing: primary
primary: internal SC oscillator (ok)
secondary: internal SC oscillator (ok)
tertiary: internal SC oscillator (ok)
auto-upgrade enabled
fabric redundancy: ok
system operational: yes
Chapter 5: Managing the System
temperature
temperature
(10C - 70C)
status
-----------
-----------
42
normal
23
normal
32
normal
32
normal
25
normal
30
normal
23
normal
25
normal
24
normal
24
normal
23
normal
Monitoring the System
auto-sync
341
Need help?