340
Monitoring the System
srp redundancy: none
*** slots: cards missing or offline
online: 6 9
standby: 8
offline: 2
empty: 0 1 3 4 5 7 10 11 12 13
line redundancy: 1 redundancy group(s)
width 6, spare 8, primary 9
temperature: ok
timing: primary
primary: internal SC oscillator (ok)
secondary: internal SC oscillator (ok)
tertiary: internal SC oscillator (ok)
auto-upgrade enabled
*** system operational: no
processor
temperature
slot
(10C - 70C)
----
-----------
0
31
3
31
5
31
7
31
processor temperature ranges
below -5C is too cold
above 80C is too hot
low temperature warning below 10C
high temperature warning above 70C
IOA temperature ranges
below -5C is too cold
above 80C is too hot
low temperature warning below 10C
high temperature warning above 70C
Example 2 Displays the environment of an E320 router
host1#show environment all
chassis: 17 slot (id 0x3, rev. 0x0)
fabric: 100 Gbps (rev. 1)
fans: fanSubsystemOk
nvs: ok (977MB flash disk, 29% full), matches running config
power: A ok, B not present
srp redundancy: mode is file-system-synchronization
enabled, switch-on-error enabled
status unknown
*** slots: cards missing or offline
online: 0 6 13
offline: 7
empty: 1 2 3 4 5 11 12 14 15 16
fabric slots: ok
online: 6 7 8 9 10
line redundancy: none
temperature: ok
timing: primary
primary: internal SC oscillator (ok)
secondary: internal SC oscillator (ok)
tertiary: internal SC oscillator (ok)
auto-upgrade enabled
fabric redundancy: ok
processor
IOA
temperature
temperature
status
(10C - 70C)
-----------
-----------
normal
30
normal
30
normal
30
normal
30
IOA
temperature
status
-----------
normal
normal
normal
normal
auto-sync