Diagnostics
2. Type the following at the Admin CLI prompt:
> analyzer save filename filename name capture_filter
>
where:
filename is the name of the file that the captured data will be saved to.
n
Determine filenames already in use:
Use the tab autocomplete feature to determine filenames that are currently in use:
> analyzer save name <tab>
test1_analyzer_capture
> analyzer save name
capture_filter is the name of a packet capture configuration. See
n
capture for the network analyzer
To determine available packet capture configurations, use the ?:
> analyzer save name ?
name: Name of the capture filter to use.
Format:
test_capture
capture_ping
> analyzer save name
The file is stored in the /etc/config/analyzer directory. To transfer the file to your PC, see
captured data to your

Download captured data to your PC

After saving captured data to a file (see
from the WebUI or from the command line by using the
  WebUI
1. Log into the IX20 WebUI as a user with Admin access.
2. On the menu, click System. Under Administration, click File System.
The File System page appears.
IX20 User Guide
for more information.
PC.
Save captured data traffic to a
test2_analyzer_capture
file), you can download the file
scp
(secure copy file) command.
Analyze network traffic
Configure packet
Download