Services
Required configuration items
Enable Ethernet bonding.
n
The mode, either:
n
Active-backup. Provides fault tolerance.
l
Round-robin. Provides load balancing as well as fault tolerance.
l
The Ethernet devices in the bonded pool.
n
  WebUI
1. Log into the IX20 WebUI as a user with full Admin access rights.
2. On the menu, click System. Under Configuration, click Device Configuration.
The Configuration window is displayed.
3. Click Network > Ethernet bonding.
4. For Add Bond device, click 
The bond device is enabled by default. To disable, click to toggle off Enable.
5. For Mode, selected either:
Active-backup: Transmits data on only one of the bonded devices at a time. When the
n
active device fails, the next available device in the list is chosen. This mode provides for
fault tolerance.
Round-robin: Alternates between bonded devices to provide load balancing as well as
n
fault tolerance.
6. Click to expand Devices.
IX20 User Guide
Ethernet network bonding
506