Digi IX20-WAG4 User Manual page 82

Table of Contents

Advertisement

Interfaces
e. For Add Test Target, click .
f. For Test type, select Ping test.
g. For Ping host, type 43.66.93.111.
h. For Ping payload size, type 256.
4. Repeat the above step for Modem to enable SureLink on that interface.
5. Click Apply to save the configuration and apply the change.
  Command line
1. Log into the IX20 command line as a user with full Admin access rights.
Depending on your device configuration, you may be presented with an Access selection
menu. Type admin to access the Admin CLI.
2. At the command line, type config to enter configuration mode:
> config
(config)>
3. Configure SureLink on ETH1:
a. Set the interval to ten seconds:
(config)> network interface eth1 ipv4 surelink interval 10s
(config)>
b. Delete the existing test targets:
(config network interface eth1> del ipv4 surelink target 0
(config network interface eth1> del ipv4 surelink target 1
(config network interface eth1)>
c. Add a test target:
(config)> add network interface eth1 ipv4 surelink target end
(config network interface eth1 ipv4 surelink target 0)>
d. Set the probe type to ping:
IX20 User Guide
Wide Area Networks (WANs)
82