94 Parameters
No.
Name/Value
01.14
Output power
-32768.00... 32767.00
kW
01.15
Output power % of
motor nom
-300.00... 300.00%
01.17
Motor shaft power
-32768.00... 32767.00
kW or hp
01.18
Inverter GWh counter
0...65535 GWh
01.19
Inverter MWh counter
0...1000 MWh
01.20
Inverter kWh counter
0...1000 kWh
01.24
Flux actual %
0...200%
01.30
Nominal torque scale
0.000...4000000
N·m or lb·ft
01.50
Current hour kWh
0.00...1000000.00 kWh
01.51
Previous hour kWh
0.00...1000000.00 kWh
Description
Measured output power in kW. The unit is selected by
96.16 Unit selection
parameter
constant can be adjusted by parameter
time power
.
Output power.
Measured output power in % of nominal motor
power.
Output power.
Estimated mechanical power at motor shaft in kW or
96.16 Unit selection
hp. Parameter
The filter time constant can be adjusted by parameter
46.14 Filter time power
Motor shaft power.
Amount of energy that has passed through the drive
(in either direction) in full gigawatt-hours. The
minimum value is zero.
Energy in GWh.
Amount of energy that has passed through the drive
(in either direction) in full megawatt-hours. Whenever
01.18 Inverter GWh counter
the counter rolls over,
incremented. The minimum value is zero.
Energy in MWh.
Amount of energy that has passed through the drive
(in either direction) in full kilowatt-hours. Whenever
01.19 Inverter MWh counter
the counter rolls over,
incremented. The minimum value is zero.
Energy in kWh.
Used flux reference in percent of nominal flux of
motor.
Flux reference.
Nominal torque in N•m which corresponds to 100%.
Note: This parameter is copied from parameter
Motor nominal torque
value is calculated from other motor data.
Nominal torque.
Current hour energy consumption. This is the energy
of the last 60 minutes (not necessarily continuous)
the drive has been running, not the energy of a
calendar hour. The value is set to the value before the
power cycle when the drive is again up and running.
Energy.
Previous hour energy consumption. The value
hour kWh
is stored here when its values has been
cumulated for 60 minutes. The value is set to the
value before the power cycle when the drive is again
up and running.
Energy.
. The filter time
46.14 Filter
defines the unit.
.
if given. Otherwise the
Default
FbEq 16
-
See par.
46.04
-
10 = 1%
-
See par.
46.04
-
1 = 1 GWh
-
is
1 = 1 MWh
-
is
10 = 1 kWh
-
1 = 1%
0
99.12
1 = 100 unit
- / -
1 = 1 kWh
Current
-
1 = 1 kWh

Advertisement