ABB ACS280 Firmware Manual page 131

Coldplate drives
Hide thumbs Also See for ACS280:
Table of Contents

Advertisement

No.
Name/Value
Embedded fieldbus
20.07
Ext2 start trigger type
Edge
Level
20.08
Ext2 in1 source
20.09
Ext2 in2 source
20.10
Ext2 in3 source
20.11
Run enable stop mode
Coast
Ramp
Torque limit
20.12
Run enable 1 source
Not used
Used
DI1
DI2
DI3
DI4
Supervision 1
Supervision 2
Supervision 3
Description
Start; stop and direction commands through
embedded fieldbus protocol when EXT1 is active.
Note: The start signal is always level-triggered with
this setting regardless of parameter
trigger type
.
Defines whether the start signal for external control
location EXT2 is edge-triggered or level-triggered.
Note: This parameter is not effective if a pulse-type
start signal is selected. See the descriptions of the
selections of parameter
The start signal is edge-triggered.
The start signal is level-triggered.
Selects source 1 for parameter
For the available selections, see parameter
in1 source
.
Selects source 2 for parameter
For the available selections, see parameter
in1 source
.
Selects source 3 for parameter
For the available selections, see parameter
in1 source
.
Selects the way the motor is stopped when the run
enable signal switches off.
The source of the run enable signal is selected by
20.12 Run enable 1 source
parameter
Stop by switching off the output semiconductors of
the drive. The motor coasts to a stop.
WARNING! If a mechanical brake is used,
ensure it is safe to stop the drive by coasting.
Stop along the active deceleration ramp. See
23 Speed reference ramp
parameter group
Stop according to torque limits (parameters
30.20
and
).
Selects the source of the external run enable signal. If
the run enable signal is switched off, the drive will not
start. If already running, the drive will stop according
to the setting of parameter
mode
.
1 = Run enable signal on.
20.19 Enable start command
See also parameter
0.
1.
10.02 DI delayed status
Digital input DI1 (
10.02 DI delayed status
Digital input DI2 (
10.02 DI delayed status
Digital input DI3 (
10.02 DI delayed status
Digital input DI4 (
32.01 Supervision status
Bit 0 of
32.01 Supervision status
Bit 1 of
32.01 Supervision status
Bit 2 of
20.02 Ext1 start
20.06 Ext2 commands
.
20.06 Ext2 commands
20.03 Ext1
20.06 Ext2 commands
20.03 Ext1
20.06 Ext2 commands
20.03 Ext1
.
.
30.19
20.11 Run enable stop
, bit 0).
, bit 1).
, bit 2).
, bit 3).
.
.
.
Parameters 131
Default
FbEq 16
14
Level
0
1
Always off
.
Always off
.
Always off
.
Coast
0
1
2
Selected
.
0
1
2
3
4
5
24
25
26

Advertisement

Table of Contents
loading

Table of Contents