244 Parameters
No.
Name/Value
44.13
Brake close delay
0.00...60.00 s
44.14
Brake close level
0.00...1000.00 rpm
45
45 Energy efficiency
45.01
Saved GW hours
0...65535 GWh
45.02
Saved MW hours
0...999 MWh
45.03
Saved kW hours
0.0...999.9 kWh
45.04
Saved energy
0.0...214748364.7 kWh
Description
Specifies a delay between a close command (that is,
when the brake control output is de-energized) and
when the drive stops modulating. This is to keep the
motor live and under control until the brake actually
closes.
Set this parameter equal to the value specified by the
brake manufacturer as the mechanical make-up time
of the brake.
Brake close delay.
Defines the brake close speed as an absolute value.
After motor speed has decelerated to this level, a
close command is given.
Brake close speed.
Settings for the energy saving calculators.
Energy saving calculators
See also section
Energy saved in GWh compared to direct-on-line
motor connection. This parameter is incremented
45.02 Saved MW hours
when
This parameter is read-only (see parameter
Energy calculations reset
Energy savings in GWh.
Energy saved in MWh compared to direct-on-line
motor connection. This parameter is incremented
45.03 Saved kW hours
when
When this parameter rolls over, parameter
Saved GW hours
is incremented.
This parameter is read-only (see parameter
Energy calculations reset
Energy savings in MWh.
Energy saved in kWh compared to direct-on-line
motor connection.
If the internal brake chopper of the drive is enabled,
all energy fed by the motor to the drive is assumed to
be converted into heat, but the calculation still
records savings made by controlling the speed. If the
chopper is disabled, then regenerated energy from
the motor is also recorded here.
When this parameter rolls over, parameter
Saved MW hours
is incremented.
This parameter is read-only (see parameter
Energy calculations reset
Energy savings in kWh.
Energy saved in kWh compared to direct-on-line
motor connection.
This parameter is read-only (see parameter
Energy calculations reset
Energy savings in kWh.
(page
rolls over.
45.21
).
rolls over.
45.01
45.21
).
45.02
45.21
).
45.21
).
Default
FbEq 16
0.00 s
100 = 1 s
10.00 rpm
See par.
46.01
80
).
-
1 = 1 GWh
-
1 = 1 MWh
-
10 = 1 kWh
-
1 = 1 kWh