182 Parameters
No.
Name/Value
30.11
Minimum speed
-30000.00...30000.00
rpm
30.12
Maximum speed
-30000.00... 30000.00
rpm
Description
Defines together with
speed range. See the figure below.
A positive (or zero) minimum speed value defines two
ranges, one positive and one negative.
A negative minimum speed value defines one range.
WARNING! The absolute value of
Minimum speed
30.12 Maximum speed
WARNING! In speed control mode only. In
frequency control mode, use frequency limits
30.13
30.14
(
and
Speed
30.12
Speed range allowed
0
30.11
Speed
30.12
Speed range allowed
30.11
0
-30.11
Speed range allowed
-30.12
Minimum allowed speed.
Defines together with
speed range. See parameter
Note: This parameter does not affect the speed
acceleration and deceleration ramp times. See
46.01 Speed scaling
parameter
WARNING! The absolute value of
Maximum speed
Minimum speed
WARNING! In speed control mode only. In
frequency control mode, use frequency limits
30.13
30.14
(
and
Maximum speed.
30.12 Maximum speed
30.11
must not be higher than the
.
).
30.11
value is < 0
30.11
value is > 0
30.11 Minimum speed
allowed
30.11 Minimum speed.
.
30.12
must not be lower than
.
).
Default
FbEq 16
allowed
-1500.00
rpm
Time
Time
See par.
46.01
1500.00 rpm
30.11
See par.
46.01