Fieldbus control through the embedded fieldbus interface (EFB)
362
Bit
Name
16
FB_LOCAL_CTL
17
FB_LOCAL_REF
18
Reserved for
RUN_DISABLE_1
19
Reserved
20
Reserved
21
Reserved
22
USER_0
23
USER_1
24
USER_2
25
USER_3
26
Reserved
...31
Status Word
Status Word for the ABB Drives profile
The table below shows the fieldbus Status Word for the ABB Drives control
profile. The embedded fieldbus interface converts the drive Status Word into
this form for the fieldbus. The upper case boldface text refers to the states
shown in
State transition diagram for the ABB Drives profile
Bit
Name
0
RDY_ON
1
RDY_RUN
2
RDY_REF
3
TRIPPED
4
OFF_2_STATUS
5
OFF_3_STATUS
Value
1
Local mode for control from the fieldbus is requested.
Steal control from the active source.
0
1
Local mode for reference from the fieldbus is
requested. Steal reference from the active source.
0
Writable control bits that can be combined with drive
logic for application-specific functionality.
Value
1
0
1
0
1
0
OPERATION INHIBITED. See also parameter
Start inhibit status word
1
0
1
0
1
0
State/Description
(no op)
(no op)
Not yet implemented.
on page
STATE/Description
READY TO SWITCH ON.
NOT READY TO SWITCH ON.
READY TO OPERATE.
OFF1 ACTIVE.
OPERATION ENABLED.
FAULT.
No fault.
OFF2 inactive.
OFF2 ACTIVE.
OFF3 inactive.
OFF3 ACTIVE.
.
365
06.18
(page 105).