ABB ACS280 Firmware Manual page 405

Coldplate drives
Hide thumbs Also See for ACS280:
Table of Contents

Advertisement

Fieldbus control through the embedded fieldbus interface (EFB)
Sub-
Index
Name
index
1800h 0
Number Of
Entries
1
COB-ID
2
Transmission
Type
3
Inhibit Time
5
Event Timer
1805h 0
Number Of
Entries
1
COB-ID
2
Transmission
Type
3
Inhibit Time
5
Event Timer
1814h 0
Number Of
Entries
1
COB-ID
2
Transmission
Type
3
Inhibit Time
5
Event Timer
Type
Access Description
U8
RO
Contain the communication parameters of
the PDOs the device sends.
Sub-index 0 contains the number of PDO-
U32
RW
parameters implemented.
U8
RW
Sub-index 1 describes the COB-ID for the
PDO. If bit 31 is set the PDO is disabled.
U6
RW
Sub-index 2 defines the transmission
mode.
U6
RW
Sub-index 3 defines inhibit time (10 =
U8
RO
1ms).
Sub-index 5 defines a timeout for
U32
RW
asynchronous PDOs.
U8
RW
U6
RW
U6
RW
U8
RO
U32
RW
U8
RW
U6
RW
U6
RW
405

Advertisement

Table of Contents
loading

Table of Contents