No.
Name/Value
22.86
Speed reference act 6
-30000.00... 30000.00
rpm
22.87
Speed reference act 7
-30000.00... 30000.00
rpm
23
23 Speed reference ramp
23.01
Speed ref ramp input
-30000.00... 30000.00
rpm
23.02
Speed ref ramp output
-30000.00... 30000.00
rpm
23.11
Ramp set selection
Acc/Dec time 1
Acc/Dec time 2
DI1
DI2
DI3
DI4
EFB DCU CW bit 10
Other [bit]
Description
Displays the value of the speed reference (Ext1 or
Ext2) that has been selected by
selection
. See diagram at
control chain diagram on page
This parameter is read-only.
Speed reference after additive 2.
Displays the value of speed reference before
application of critical speeds. See the control chain
418
diagram on page
.
The value is received from
unless overridden by
• any constant speed
• a jogging reference
• network control reference
• control panel reference
• safe speed reference.
This parameter is read-only.
Speed reference before application of critical speeds.
Speed reference ramp settings (programming of the
acceleration and deceleration rates for the drive).
See the control chain diagram on page
Displays the used speed reference (in rpm) before it
enters the ramping and shaping functions. See the
control chain diagram on page
This parameter is read-only.
Speed reference before ramping and shaping.
Displays the ramped and shaped speed reference in
rpm. See the control chain diagram on page
This parameter is read-only.
Speed reference after ramping and shaping.
Selects the source that switches between the two
sets of acceleration/deceleration ramp times defined
23.12
by parameters
...
0 = Acceleration time 1, deceleration time 1 and shape
time 1 are active.
1 = Acceleration time 2, deceleration time 2 and shape
time 2 are active.
0.
1.
10.02 DI delayed status
Digital input DI1 (
10.02 DI delayed status
Digital input DI2 (
10.02 DI delayed status
Digital input DI3 (
10.02 DI delayed status
Digital input DI4 (
Only for the DCU profile. DCU control word bit 10
received through the embedded fieldbus interface.
Terms and abbreviations
Source selection (see
19.11 Ext1/Ext2
22.11 Ext1 speed ref1
418
.
22.86 Speed reference act 6
420
.
420
.
420
23.15
, bit 0).
, bit 1).
, bit 2).
, bit 3).
Parameters 155
Default
FbEq 16
0.00 rpm
or the
See par.
46.01
0.00 rpm
See par.
46.01
-
See par.
46.01
-
.
See par.
46.01
DI1
0
1
2
3
4
5
20
).
-