ABB ACS280 Firmware Manual page 283

Coldplate drives
Hide thumbs Also See for ACS280:
Table of Contents

Advertisement

No.
Name/Value
97.13
IR compensation
0.00...50.00%
Description
Defines the relative output voltage boost at zero
speed (IR compensation). The function is useful in
applications with a high break-away torque where
vector control cannot be applied.
U
U
/
N
(%)
Relative output voltage. IR
compensation set to 15%.
100%
15%
Field weakening point
50% of nominal
frequency
IR compensation for scalar motor
See also section
control
36
on page
.
Typical IR compensation values are shown below.
3-phase 180...480V drives
P
(kW)
0, 37 0, 75 1, 1
N
IR
3, 5
3, 5 3, 2 2, 5
compens
-ation
(%)
3-phase 200...240V drives
P
(kW)
0, 37 0, 75 1, 1
N
IR
3, 5
3, 5 2, 6 2, 4 2, 2 1, 7
compens
-ation
(%)
1-phase 200...240V drives
P
(kW)
0, 37 0, 75 1, 1
N
IR
3, 0
2, 3 2, 0 1, 7 1, 5
compens
-ation
(%)
WARNING! Set IR compensation value as low as
possible. Large IR compensation value can lead
to overheating of the motor and damage to
the drive, if operated for longer periods at low
speed.
Voltage boost at zero speed in percent of nominal
motor voltage.
Parameters 283
Relative output voltage.
No IR compensation.
2, 2
4
7, 5
15
22
2
1, 5 1, 25 1, 2
2, 2
3
7, 5
11
1, 5
1, 5 2, 2
Default
FbEq 16
3.20%
f
(Hz)
1 = 1%