ABB ACS280 Firmware Manual page 197

Coldplate drives
Hide thumbs Also See for ACS280:
Table of Contents

Advertisement

No.
Name/Value
32
32 Supervision
32.01
Supervision status
Bit
Name
0
Supervision 1 active
1
Supervision 2 active
2
Supervision 3 active
3
Supervision 4 active
4
Supervision 5 active
5
Supervision 6 active
6...15
Reserved
0000h...FFFFh
32.05
Supervision 1 function
Disabled
Low
High
Abs low
Abs high
Description
Configuration of signal supervision functions 1...3.
Three values can be chosen to be monitored; a
warning or fault is generated whenever predefined
limits are exceeded.
Signal supervision
See also section
Signal supervision status word.
Indicates whether the values monitored by the signal
supervision functions are within or outside their
respective limits.
Note: This word is independent of the drive actions
defined by parameters
32.56
and
.
Description
1 = Signal selected by
1 = Signal selected by
1 = Signal selected by
1 = Signal selected by
1 = Signal selected by
1 = Signal selected by
Signal supervision status word.
Selects the mode of signal supervision function 1.
Determines how the monitored signal (see parameter
32.07
) is compared to its lower and upper limits
32.09
32.10
(
and
respectively). The action to be taken
when the condition is fulfilled is selected by
Signal supervision 1 not in use.
Action is taken whenever the signal is below the
Supervision 1 low limit - 0.5 * hysteresis.
Action is deactivated whenever the signal is above
the Supervision 1 low limit + 0.5 * hysteresis.
Action is taken whenever the signal is above the
Supervision 1 high limit + 0.5 * hysteresis.
Action is deactivated whenever the signal is below
the Supervision 1 high limit - 0.5 * hysteresis.
Action is taken whenever the absolute value of the
signal is below the absolute value of the Supervision 1
low limit - 0.5 * hysteresis.
Action is deactivated whenever the absolute value
of the signal is above the absolute value of the
Supervision 1 low limit + 0.5 * hysteresis.
Action is taken whenever the absolute value of the
signal is above the absolute value of the Supervision 1
high limit + 0.5 * hysteresis.
Action is deactivated whenever the absolute value
of the signal is below the absolute value of the
Supervision 1 high limit - 0.5 * hysteresis.
80
(page
).
32.06
32.16
32.26
32.36
,
,
,
32.07
is outside its limits.
32.17
is outside its limits.
32.27
is outside its limits.
32.37
is outside its limits.
32.47
is outside its limits.
32.57
is outside its limits.
32.06
Parameters 197
Default
FbEq 16
0000h
32.46
,
1 = 1
Disabled
.
0
1
2
3
4