No.
Name/Value
06.11
Main status word
0000h...FFFFh
Description
ABB Drives Profile Main status word. Reflects the
status of the drive irrespective of control source e.g. a
fieldbus system, control panel (keypad), PC-Tool,
standard I/O, application program or sequence
programming, and irrespective of the actual control
profile which is used to control the drive.
The bit assignments are described on page
(Contents of the fieldbus control word). The state
diagram (valid for ABB drives profile) is on page
This parameter is read-only.
Note: With the fieldbus control, the parameter value
is not same as the value that it receives from the PLC.
Bit
Name
0
Ready to switch ON
1
Ready run
2
Ready ref
3
Tripped
4
Off 2 inactive
5
Off 3 inactive
6
Switch-on inhibited
7
Warning
8
At setpoint
9
Remote
10
Above limit
11
User bit 0
12
User bit 1
13
User bit 2
14
User bit 3
15
0
Main status word.
Parameters 103
Default
FbEq 16
0000h
362
365
.
1 = 1