ABB ACS280 Firmware Manual page 401

Coldplate drives
Hide thumbs Also See for ACS280:
Table of Contents

Advertisement

Fieldbus control through the embedded fieldbus interface (EFB)
Communication profile area (1000...1FFF)
Sub-
Index
Name
index
1000h 0
Device Type
1001h 0
Error Register U8
1003h 0
Number of
Errors
1
Standard
Error Field
2
Standard
Error Field
3
Standard
Error Field
4
Standard
Error Field
5
Standard
Error Field
1005h 0
COB-ID Sync
Message
1008h 0
Manufacturer
Device Name
1009h 0
Manufacturer
Software
Version
100Ch 0
Guard Time
100Dh 0
Life Time
Factor
Type
Access Description
U32
RO
The device type specifies the kind of
device. The lower 16 bits contain the
device profile number and the upper 16
bits additional information depending on
the profile.
RO
The error register is a field of 8 bits, each
for a certain error type. If an error occurs
the bit is set.
Bit Meaning
0 generic error, always set on error
1 current
2 voltage
3 temperature
4 communication error (overrun, error
state)
5 device profile specific
6 reserved
7 manufacturer specific
U8
RW
This object holds errors that have
occurred on the device and have been
signaled via Emergency Object.
U32
RO
The most recent error is at sub-index 1.
When a new error occurs, the previous
U32
RO
errors move down the list. See
tracing
meaning of error codes. Writing 0 to sub
U32
RO
index 0 deletes the entire error history.
U32
RO
NOTE: Only sub-indices up to 1001h:0h
(Number of Errors) can be read. E.g. if
U32
RO
Number of Errors is 2, reading 1001h:2h is
possible, but attempting to read 1001h:3h
U32
RW
causes an SDO abort.
Visible
Const
Contains the device name.
string
Visible
RW
Contains the device software version.
string
U6
RW
This entry contains the guard time in ms.
The value 0 means, that the guard time is
not used.
U8
RW
The life time factor multiplied with the
guard time gives the life time for the
device.
If it is 0, it is not used.
on page
389
for details on the
401