ABB ACS280 Firmware Manual page 168

Coldplate drives
Hide thumbs Also See for ACS280:
Table of Contents

Advertisement

168 Parameters
No.
Name/Value
Follow Ext1/Ext2
selection
DI1
DI2
DI3
DI4
Other [bit]
26.17
Torque ref filter time
0.000...30.000 s
26.18
Torque ramp up time
0.000...60.000 s
26.19
Torque ramp down
time
0.000...60.000 s
26.20
Torque reversal
Always off
Always on
DI1
DI2
DI3
DI4
Supervision 1
Supervision 2
Supervision 3
Supervision 4
Supervision 5
Supervision 6
Other [bit]
26.70
Torque reference act 1
-1600.0...1600.0%
Description
Torque reference 1 is used when external control
location EXT1 is active. Torque reference 2 is used
when external control location EXT2 is active.
19.11 Ext1/Ext2 selection
See also parameter
10.02 DI delayed status
Digital input DI1 (
10.02 DI delayed status
Digital input DI2 (
10.02 DI delayed status
Digital input DI3 (
10.02 DI delayed status
Digital input DI4 (
Terms and abbreviations
Source selection (see
Defines a low-pass filter time constant for the torque
reference.
Filter time constant for torque reference.
Defines the torque reference ramp-up time, ie. the
time for the reference to increase from zero to
nominal motor torque.
Torque reference ramp-up time.
Defines the torque reference ramp-down time, ie. the
time for the reference to decrease from nominal
motor torque to zero.
Torque reference ramp-down time.
Inverts the torque reference or selects the source for
the inversion signal.
Torque reversal is located in the torque reference
chain after torque reference act 3 signal, so the
inversion is visible in torque reference act 4 signal.
Torque reference is not inverted.
Torque reference is inverted.
Digital input DI1 (
10.02 DI delayed status
10.02 DI delayed status
Digital input DI2 (
10.02 DI delayed status
Digital input DI3 (
10.02 DI delayed status
Digital input DI4 (
32.01 Supervision status
Bit 0 of
32.01 Supervision status
Bit 1 of
32.01 Supervision status
Bit 2 of
32.01 Supervision status
Bit 3 of
32.01 Supervision status
Bit 4 of
32.01 Supervision status
Bit 5 of
Terms and abbreviations
Source selection (see
Displays the value of torque reference source 1
(selected by parameter
the control chain diagram on page
This parameter is read-only.
Value of torque reference source 1.
.
, bit 0).
, bit 1).
, bit 2).
, bit 3).
, bit 0).
, bit 1).
, bit 2).
, bit 3).
.
.
.
.
.
.
26.11 Torque ref1 source
423
.
Default
FbEq 16
2
3
4
5
6
).
-
0.000 s
1000 = 1 s
0.000 s
100 = 1 s
0.000 s
100 = 1 s
Always off
0
1
2
3
4
5
24
25
26
27
28
29
).
-
-
). See
See par.
46.03

Advertisement

Table of Contents
loading

Table of Contents