ABB ACS280 Firmware Manual page 217

Coldplate drives
Hide thumbs Also See for ACS280:
Table of Contents

Advertisement

No.
Name/Value
Speed ref ramp out
Speed ref used
Torque ref used
Freq ref used
Process PID out
Other
36.02
PVL filter time
0.00...120.00 s
36.06
AL2 signal source
36.07
AL2 signal scaling
0.00...32767.00
36.09
Reset loggers
Done
All
PVL
AL2
36.10
PVL peak value
-32768.00... 32767.00
36.11
PVL peak date
1/1/1980...6/5/2159
36.12
PVL peak time
-
36.13
PVL current at peak
-32768.00... 32767.00 A
Description
23.02 Speed ref ramp output
24.01 Used speed reference
26.02 Torque reference used
28.02 Frequency ref ramp output
40.01 Process PID output actual
Terms and abbreviations
Source selection (see
Peak value logger filtering time. See parameter
PVL signal source
.
Peak value logger filtering time.
Selects the signal to be monitored by amplitude
logger 2. The signal is sampled at 200 ms intervals.
The results are displayed by parameters
36.49
. Each parameter represents an amplitude
range, and shows what portion of the samples fall
within that range.
The signal value corresponding to 100% is defined by
36.07 AL2 signal scaling
parameter
Amplitude logger 2 can be reset using parameter
36.09 Reset loggers
. The date and time of the last
reset are stored into parameters
respectively.
For the selections, see parameter
source
.
36.01
See parameter
for the selections.
Defines the monitored signal value for the amplitude
logger AL2 that corresponds to 100% sample value.
Signal value corresponding to 100%.
Resets the peak value logger and/or amplitude logger
2. (Amplitude logger 1 cannot be reset.)
Reset completed or not requested (normal
operation).
Reset both the peak value logger and amplitude
logger 2.
Reset the peak value logger.
Reset amplitude logger 2.
Shows the peak value recorded by the peak value
logger.
Peak value.
Shows the date when the peak value was recorded.
Peak occurrence date.
Shows the time when the peak value was recorded.
Peak occurrence time.
Shows the Motor current at the moment the peak
value was recorded.
Motor current at peak.
Parameters 217
.
.
.
.
.
).
36.01
36.40
...
.
36.50
36.51
and
36.01 PVL signal
Default
FbEq 16
11
12
13
14
16
-
2.00 s
100 = 1 s
Motor
torque
100.00
1 = 1
Done
0
1
2
3
0.00
1 = 1
01/01/1980
-
00:00:00
-
0.00 A
1 = 1 A