display rmon prialarm

Use display rmon prialarm to display entries in the private RMON alarm table.
Syntax
display rmon prialarm [ entry-number ]
Views
Any view
Predefined user roles
network-admin
network-operator
mdc-admin
mdc-operator
Parameters
entry-number: Specifies an alarm entry index in the range of 1 to 65535. If no entry is specified, the
command displays all private alarm entries.
Examples
# Display all private alarm entries.
<Sysname> display rmon prialarm
PrialarmEntry 1 owned by user1 is VALID.
Sample type
Variable formula
Description
Sampling interval (in seconds)
Rising threshold
Falling threshold
Alarm sent upon entry startup
Entry lifetime : forever
Latest value
Table 37 Command output
Field
PrialarmEntry entry-number
owned by owner is status.
: absolute
: (.1.3.6.1.2.1.16.1.1.1.6.1*100/.1.3.6.1.2.1.16.1.1.1.5.1)
: ifUtilization.GigabitEthernet3/0/1
: 10
: 80(associated with event 1)
: 5(associated with event 2)
: risingOrFallingAlarm
: 85
Description
Alarm entry owner and status:
entry-number—Alarm entry index (MIB object
hh3cRmonExtAlarmIndex).
owner—Entry owner (MIB object hh3cRmonExtAlarmOwner).
status—Entry status (MIB object hh3cRmonExtAlarmStatus):
VALID—The entry is valid.
UNDERCREATION—The entry is invalid.
The status field is not configurable at the CLI. All alarm entries created from
the CLI are valid by default.
The display rmon prialarm command can display invalid entries, but the
display current-configuration and display this commands do not display
their settings.