Chapter 12 Description of Parameter SettingsCT2000 Series
Release Brake Check Time
Settings
Multi-function output terminal: Function 42: Brake Current Checking Point
Settings
Multi-function output terminal: Function 42: Brake Frequency Checking Point
Settings
 Pr02-32, Pr02-33, Pr02-34, Pr02-57 and Pr02-58 can be applied on setting up cranes. (Choose
crane action #42 to set up multi-functional output Pr02-13, Pr02-14, Pr02-16, and Pr02-17)
 When output current of a drive is higher than the setting of Pr02-33 Pivot Point of the Current
(>=02-33) and when output frequency is higher than the setting of Pr02-34 Pivot Point of the
Frequency (>= 02-34), choose #42 to set up Multi-functional output Pr02-13, Pr02-14, Pr02-16
and Pr002-17 after the delay time set at Pr402-32.
 When the Pivot Point of the Current 's setting 02-57≠0 and when the output current of the drive is
lower than the setting of Pr02-57 (<02-57), or when the output frequency is lower than the setting
of Pr02-58 (<02-58), the disable the setting #42 of the multi-functional output Pr02-13, Pr02-14,
Pr02-16, Pr02-17
 When Pr02-57 = 0, the output current is lower than setting of Pr02-33 Pivot Point of the
Current(<02-33) or when output frequency is lower than the setting of Pr02-58(<02-58), disable
the setting of #42 of the multi-functional output Pr02-13, Pr02-14, Pr02-16, Pr02-17.
~
Reserved
Speed Area Band
Settings
~
Reserved
IO Card Type
Settings
0: No IO card
1: EMC-BPS01
.000~65.000 sec.
0~100%
0.00~3.00Hz
0.00~599.00Hz
Read only
12.1-02-24
Factory Setting: 0.000
Factory setting: 0
Factory setting:0.00
Factory Setting: 0.00
Factory Setting: Read only