Chapter 12 Description of Parameter SettingsCT2000 Series
Settings
Functions
st
The 1
, 2
8
or deceleration time
selection
rd
The 3
, 4
9
or deceleration time
selection
EF Input (EF: External
10
fault)
External B.B. Input (Base
11
Block)
12
Output Stop
Cancel the setting of the
13
optimal accel./decel. time
Switch between drive
14
settings 1 and 2
Operation speed
15
command form AVI
Operation speed
16
command form ACI
Operation speed
17
command form AUI
18
Emergency Stop (07-20)
19
Digital Up command
Fr eq ue ncy
S etti ng
fr eq ue ncy
MIx- GND
O pe ra tio n
co mman d
nd
acceleration
The acceleration/deceleration time of the drive could be selected
from this function or the digital status of the terminals; there are 4
th
acceleration
acceleration/deceleration speeds in total for selection.
External fault input terminal. It will decelerate by Pr.07-20 setting (it
will have fault record when external fault occurs)
When this contact is ON, output of the drive will be cut off
immediately, and the motor will be free run and display B.B. signal.
Refer to Pr.07-08 for details.
If this contact is ON, output of the drive will be cut off immediately,
and the motor will then be free run. And once it is turned to OFF,
the drive will accelerate to the setting frequency.
V ol tag e
S etti ng
fr eq ue ncy
MI - GND
O pe ra tio n
co mman d
Before using this function, Pr.01-44 should be set to 01/02/03/04
first. When this function is enabled, OFF is for auto mode and ON
is for linear accel./decel.
When the contact is ON: use motor 2 parameters.
motor 1 parameters.
When the contact is ON, the source of the frequency will force to be
AVI. (If the operation speed commands are set to AVI, ACI and AUI
at the same time. The priority is AVI>ACI>AUI)
When the contact is ON, the source of the frequency will force to be
ACI. (If the operation speed commands are set to AVI, ACI and AUI
at the same time. The priority is AVI>ACI>AUI)
When this function is enabled, the source of the frequency will
force to be AUI. (If the operation speed commands are set to AVI,
ACI and AUI at the same time. The priority is AVI>ACI>AUI)
When the contact is ON, the drive will ramp to stop by Pr.07-20
setting.
When the contact is ON, the frequency will be increased and
decreased. If this function is constantly ON, the frequency will be
Descriptions
A ccel . in hi bi t
a re a
A ccel . in hi bi t
a re a
A ctua l o pe ra tio n fr eq ue ncy
O N
O N
O N
Fr eq ue ncy
x
12.1-02-4
De cel . in hi bi t
a re a
A ctua l o pe ra tio n
fr eq ue ncy
De cel . in hi bi t
a re a
O N
O N
O FF
O FF
O N
ON
O N
Ti me
Ti me
OFF: use