Rated Power of Induction Motor 1(kW)
Settings
 It is used to set rated power of the motor 1. The factory setting is the power of the drive.
Rated Speed of Induction Motor 1 (rpm)
Settings
 It is used to set the rated speed of the motor and need to set according to the value indicated on
the motor nameplate.
Pole Number of Induction Motor 1
Settings
 It is used to set the number of motor poles (must be an even number).
No-load Current of Induction Motor 1 (A)
Settings
 The factory setting is 40% of rated current.
Stator Resistance(Rs) of Induction Motor 1
Rotor Resistance(Rr) of Induction Motor 1
Settings
Magnetizing Inductance(Lm) of Induction Motor 1
Stator inductance(Lx) of Induction Motor 1
Settings
~
Reserved
Full-load Current of Induction Motor 2(A)
Settings
 This value should be set according to the rated frequency of the motor as indicated on the motor
Chapter 12 Description of Parameter SettingsCT2000 Series
0~655.35 kW
0~xxxx (Depends on the power of motor)
2~64
0 to the factory setting in Pr.05-01
0~65.535Ω
0~6553.5mH
0~xxxx (Depends on the power of motor)
12.1-05-4
Factory Setting: #.##
Factory Setting:
Depends on the power
of motor
Factory Setting: 4
Unit: Amper
Factory Setting: #.##
Factory Setting: #.###
Factory Setting: #.#
Unit: Amper
Factory Setting:#.##