Rated Power of Induction Motor 1(kW)
Settings
It is used to set rated power of the motor 1. The factory setting is the power of the drive.
Rated Speed of Induction Motor 1 (rpm)
Settings
It is used to set the rated speed of the motor and need to set according to the value indicated on
the motor nameplate.
Pole Number of Induction Motor 1
Settings
It is used to set the number of motor poles (must be an even number).
No-load Current of Induction Motor 1 (A)
Settings
The factory setting is 40% of rated current.
Stator Resistance(Rs) of Induction Motor 1
Rotor Resistance(Rr) of Induction Motor 1
Settings
Magnetizing Inductance(Lm) of Induction Motor 1
Stator inductance(Lx) of Induction Motor 1
Settings
~
Reserved
Full-load Current of Induction Motor 2(A)
Settings
This value should be set according to the rated frequency of the motor as indicated on the motor
Chapter 12 Description of Parameter SettingsCT2000 Series
0~655.35 kW
0~xxxx (Depends on the power of motor)
2~64
0 to the factory setting in Pr.05-01
0~65.535Ω
0~6553.5mH
0~xxxx (Depends on the power of motor)
12.1-05-4
Factory Setting: #.##
Factory Setting:
Depends on the power
of motor
Factory Setting: 4
Unit: Amper
Factory Setting: #.##
Factory Setting: #.###
Factory Setting: #.#
Unit: Amper
Factory Setting:#.##