API
RAD
D
P
116
Bit device
X
Y
M
K
S
*
D
Notes on operand usage:
Please refer to the function specifications table for each device in
series for the scope of device usage
S: data source (angle). D: result of transformation (diameter).
Uses the following formula to convert angles to radians.
Diameter =Angle × (π/180)
When X0=On, the angle of the designated binary floating point number (D1, D0)
will be converted to radians and stored in (D11, D10), with the content consisting
of a binary floating point number.
X0
Word device
H
KnX KnY KnM
T
*
DRAD
D0
Chapter 16 PLC Function CT2000 Series
Angle → Diameter
16-bit command
-
C
D
*
32-bit command (9 STEP)
*
DRAD
Continuous
execution type
Flag signal: none
D10
16-73
-
-
-
DRADP
脈波執行型