Setting
Display
*
Fault
11
LvA
Lv at accel
Fault
12
Lvd
Lv at decel
Fault
13
Lvn
Lv at normal SPD
Fault
14
LvS
Lv at stop
Fault
15
OrP
Phase Lacked
Fault
16
oH1
IGBT over heat
Fault
17
oH2
Hear Sink oH
Fault
18
tH1o
Thermo 1 open
Fault
19
tH2o
Thermo 2 open
Fault
21
oL
Inverter oL
Fault
Fault
22
EoL1
EoL2
Thermal relay 2
Thermal relay 1
Fault
code
DC BUS voltage is less than Pr.06.00 during
000BH
acceleration.
DC BUS voltage is less than Pr.06.00 during
000CH
deceleration.
DC BUS voltage is less than Pr.06.00 in
000DH
constant speed.
000EH DC BUS voltage is less than Pr.06-00 at stop
000FH Phase Loss Protection
IGBT overheat
IGBT temperature exceeds protection level.
0010H
1~15HP: 90℃
20~100HP: 100℃
Heat sink overheat
0011H
Heat sink temperature exceeds 90oC
Temperature detection circuit error (IGBT)
0012H
IGBT NTC
Temperature detection circuit error (capacity
0013H
module)
CAP NTC
Overload. The AC motor drive detects
excessive drive output current.
0015H
NOTE: The AC motor drive can withstand up to 150% of
the rated current for a maximum of 60 seconds.
0016H Electronics thermal relay 1 protection
15-27
Chapter 15 CANopen Overview CT2000 Series
Description
CANopen
CANopen
fault
fault code
(bit 0~7)
register
2
3220H
2
3220H
2
3220H
2
3220H
2
3130H
3
4310H
3
4310H
3
FF00H
3
FF01H
1
2310H
1
2310H

Hide quick links: