Upper/lower differential output commands
Command
code
PLS
Upper differential output
PLF
Lower differential output
Stop command
Command
code
END
Program conclusion
Other commands
Command
code
NOP
No action
INV
Inverse of operation results
P
Index
16-6-2 Detailed explanation of basic commands
Command
LD
Load contact a
X0~X17
Operand
The LD command is used for contact a starting at the left busbar or contact a starting
at a contact circuit block; its function is to save current content and save the acquired
contact status in the cumulative register.
Ladder diagram:
X0
Command
LDI
Load contact b
X0~X17
Operand
The LDI command is used for contact b starting at the left busbar or contact b starting
at a contact circuit block; its function is to save current content and save the acquired
contact status in the cumulative register.
Ladder diagram:
X0
Function
Function
Function
Y0~Y17
M0~M799
X1
Y1
Y0~Y17
M0~M799
X1
Y1
16-39
Chapter 16 PLC Function CT2000 Series
OPERAND
OPERAND
OPERAND
Function
T0~159
Command code:
LD
X0
AND
X1
OUT
Y1
Function
T0~159
Command code:
LDI
X0
AND
X1
OUT
Y1
Execution
speed (us)
Y、M
1.2
Y、M
1.2
Execution
speed (us)
N/A
0.2
Execution
speed (us)
N/A
0.2
N/A
0.2
P
0.3
C0~C79
D0~D399
Description:
Load Contact a of X0
Create
connection to contact a
of X1
Drive Y1 coil
C0~C79
D0~D399
Description:
Load Contact b of X0
Create
connection to contact a
of X1
Drive Y1 coil