Chapter 15 CANopen Overview CT2000 Series
NOTE01: To know the current position, read 2061-05.
NOTE02: To know if reaching the target position, read bit 0 of 2061 (0: Not reached, 1: Reached).
Home Mode
1. Set Pr00-12 to choose how to return home.
2. Set the left and right limits correspond to the position of MI terminal.
3. To switch C2000 control mode to Home mode: Set Index 6060 = 6.
4. Set 2060-01 = 0080h, then motor drive will have server on.
5. Set the ACK signal: set 2060-01 = 0081h, then the motor drive will start to go back home.
NOTE 01: To know if returning home is completed, read bit12 of 6041 ( 0: Not reached, 1: Reached).