※ From time record, it can be known that the last fault (Pr06-17) happened after the drive run for
4days and 240 minutes.
Low Current Setting Level
Settings
Low Current Detection Time
Settings
Treatment for low current
Settings
The drive will operate as the setting of Pr.06-73 when output current is lower than the setting of
Pr.06-71 and when low current continues for a period longer than the setting of Pr.06-72. This
parameter can also be used with external multi-function output terminal 44 (MO44) for low current
output.