Delta CT2000 Series User Manual page 212

Table of Contents

Advertisement

Homing by Frequency 1
Settings
Homing by Frequency 2
Settings
 Control by Multi-function Input Terminal Pr. 02-01~02-08 (44~47).
44: Reverse direction homing
45: Forward direction homing
46: Homing (ORG)
47: Homing function enable
 If the drive is not control by CAN or PLC, set Pr.00-10 =1 (Control mode = P2P position control)
and set external output terminal to 47 (homing function enable) for homing.
 When Pr.00-10 is set to 3, after homing is complete, user must set control mode setting Pr.00-10
to 1 in order to perform P2P position control.
Reserved
~
Display Filter Time (Current)
Settings: 0.001~65.535 sec
 Set this parameter to minimize the current fluctuation displayed by digital keypad.
Display Filter Time (Keypad)
Settings: 0.001~65.535 sec
 Set this parameter to minimize the display value fluctuation displayed by digital keypad.
Software Version (date)
Settings: Read only
 This parameter displays the drive's software version by date.
~
Reserved
Chapter 12 Description of Parameter SettingsCT2000 Series
0.00~599.00Hz
0.00~599.00Hz
12.1-00-19
Factory Setting: 8.00
Factory Setting: 2.00
Factory Settings: 0.100
Factory Settings: 0.100
Factory Settings: ####

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents